↓ Skip to main content

Wiley Online Library

Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: Joint recommendations by the AAPM and GEC‐ESTRO

Overview of attention for article published in Medical Physics, August 2017
Altmetric Badge

Citations

dimensions_citation
52 Dimensions

Readers on

mendeley
94 Mendeley
Title
Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: Joint recommendations by the AAPM and GEC‐ESTRO
Published in
Medical Physics, August 2017
DOI 10.1002/mp.12430
Pubmed ID
Authors

Mark J. Rivard, Facundo Ballester, Wayne M. Butler, Larry A. DeWerd, Geoffrey S. Ibbott, Ali S. Meigooni, Christopher S. Melhus, Michael G. Mitch, Ravinder Nath, Panagiotis Papagiannis

Abstract

Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1) and its 2007 supplement (TG-43U1S1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical purposes and are posted on the Brachytherapy Seed Registry managed jointly by the AAPM and the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROC Houston). Given increasingly closer interactions among physicists in North America and Europe, the AAPM and the Groupe Européen de Curiethérapie-European Society for Radiotherapy & Oncology (GEC-ESTRO) have prepared another supplement containing recommended brachytherapy dosimetry parameters for eleven low-energy photon-emitting brachytherapy sources. The current report presents consensus datasets approved by the AAPM and GEC-ESTRO. The following sources are included: (125) I sources (BEBIG model I25.S17, BEBIG model I25.S17plus, BEBIG model I25.S18, Elekta model 130.002, Oncura model 9011, and Theragenics model AgX100); (103) Pd sources (CivaTech Oncology model CS10, IBt model 1031L, IBt model 1032P, and IsoAid model IAPd-103A); and (131) Cs (IsoRay Medical model CS-1 Rev2). Observations are included on the behavior of these dosimetry parameters as a function of radionuclide. Recommendations are presented on the selection of dosimetry parameters, such as from societal reports issuing consensus datasets (e.g., TG-43U1, AAPM Report #229), the joint AAPM/IROC Houston Registry, the GEC-ESTRO website, the Carleton University website, and those included in software releases from vendors of treatment planning systems. Aspects such as timeliness, maintenance, and rigor of these resources are discussed. Links to reference data are provided for radionuclides (radiation spectra and half-lives) and dose scoring materials (compositions and mass densities). The recent literature is examined on photon energy response corrections for thermoluminescent dosimetry of low-energy photon-emitting brachytherapy sources. Depending upon the dosimetry parameters currently used by individual physicists, use of these recommended consensus datasets may result in changes to patient dose calculations. These changes must be carefully evaluated and reviewed with the radiation oncologist prior to their implementation. This article is protected by copyright. All rights reserved.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 94 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 94 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 16 17%
Other 13 14%
Student > Master 11 12%
Student > Ph. D. Student 8 9%
Professor > Associate Professor 7 7%
Other 13 14%
Unknown 26 28%
Readers by discipline Count As %
Physics and Astronomy 38 40%
Medicine and Dentistry 10 11%
Engineering 3 3%
Agricultural and Biological Sciences 3 3%
Computer Science 1 1%
Other 6 6%
Unknown 33 35%